APPLICATION
Servers, Data centers, Critical network
devices, Sensitive electronic equipment,
Telecom...
KEY
FEATURES
l
True
on-line double conversion technology with
advanced microprocessor control
l
Wide
input voltage range
l
Zero
transfer time
l Protection
against all type of power problems
l Self
test while start of the UPS
l Site
wiring fault warning
l On-battery
power-on function
l Smart
RS232 communication interface
l Intelligent
slot available
l Sealed
lead-acid, maintenance free battery |
|
|
|
|
TECHNICAL
SPECIFICATIONS
|
Product
Series
|
Rack
Mount 1~6kVA
|
|
Model
|
C1KR
|
C2KR
|
C3KR
|
C6KR
|
|
Rated
Power
|
VA/W
|
1kVA/0.7kW
|
2kVA/1.4kW
|
3kVA/2.1kW
|
6kVA/4.2kW
|
|
Input
|
Nominal
Voltage
|
220VAC
|
|
Voltage
Range
|
115
~ 300VAC
|
176
~ 276VAC
|
|
Frequency
Range
|
46
~ 54Hz(default), user adjustable within 40~60Hz
|
46
~ 54Hz
|
|
Power
Factor
|
0.97
|
0.98
|
|
Connection
|
IEC320-10A
inlet
|
IEC320-16A
inlet
|
Terminal
Block
|
|
Output
|
Voltage
|
220VAC
¡À
2%
|
220VAC
¡À
1%
|
|
Frequency
|
46~54Hz
or 50Hz ¡À
0.2Hz (Line mode)
50Hz ¡À
0.2Hz (
Battery
mode)
|
46~54Hz
(Line mode)
50Hz ¡À
0.05Hz (
Battery
mode)
|
|
Waveform
|
Sine
Wave
|
|
Overload
Capability
|
108%~150%
for 30 sec., ³150%
for 300 ms
|
105%~130%
for 10 min., ³130%
for 1 min.
|
|
Current
Crest Ratio
|
3:1
|
|
Bypass
|
Automatic
Transfer
|
on
overload and UPS failure
|
|
Before
UPS Power-on
|
Default
¡°NO¡±, user adjustable to ¡°YES¡±
|
Yes
|
|
Voltage
Range
|
80~264VAC
(Default), user adjustable within 80~286VAC
|
176
~ 261VAC
|
|
Output
Connections
|
IEC320
-10A * 4
|
IEC320-10A
* 4
|
IEC320-10A
and
Terminal Block
|
IEC320-10A
* 4 and Terminal Block
|
|
Transfer
Time
|
0
ms; less than 4 ms from inverter to bypass and vice
versa
|
Zero
|
|
LED
indicators
|
Status
|
Load
level /
Battery
level,
Battery
,
Utility Power, Inverter, Bypass, Overload, Fault
|
|
Audible
Alarm
|
Bypass,
On battery mode,
Battery
low,
Overload, Fault
|
|
Communications
|
RS-232
Serial Interface
|
|
|
|
Network
Surge Protection
|
RJ45
I/O port available for network or Fax/Modem
|
|
Environmental
|
Operating
Temperature
|
0
~ 40¡ãC
|
|
Operating
Humidity
|
20
~ 90% non-condensing
|
|
Main
Unit
|
Net
Weight (Kg)
|
15.0
|
9.6
|
10.0
|
18.3
|
|
Dimensions
(W x D x H) mm
|
482
x 420 x 88 (2U)
|
482.6
x 600 x 130 (3U)
|
|
Battery
Pack
|
Type
|
Internal
Batteries
|
External
Battery
Pack
|
|
Nominal
DC Voltage
|
36VDC
|
96VDC
|
240VDC
|
|
Backup
Time (Full load)
|
5
min
|
9
min
(with 1 BP)
|
5
min
(with 1 BP)
|
7
min
(with 1 BP)
|
|
Net
Weight (Kg)
|
--
|
26.0
|
64.2
|
|
Dimensions
(W x D x H) mm
|
--
|
482
x 420 x 88 (2U)
|
482.6
x 600 x 130 (3U)
|
Notes:
C1KRS,
C2KRS, C3KRS & C6KRS for longer Backup time with
additional Battery Packs are available, please consult
local distributors.
Specifications are subject to change without notice
|
|
|