| Following
the popularity of computer networks and the
continual upgrades of information processing
technology, there is now virtually no limits
for network information transmissions.
Undoubtedly, the server is the soul of a
computer network which processes numerous
network data day in and day out and is
naturally more demanding in terms of power
requirements computers in general. Any
increase of power network load, excessively
low voltage, unstable frequency or even a
sudden power-off can interrupt normal
network operations!
In line
with the power requirements for network
system, Santak has developed a new
generation of on-line intelligent
UPS---CASTLE Series 1K, 2K, 3K UPS. Its uses
the Motorola microprocessor with robust
processing power which is capable of
detecting and controlling quickly and
accurately all movements of the UPS to
ensure high product reliability. In addition
to providing the network with power
protection for virtually zero interruption,
regulated voltage and regulated frequency,
interference-resistant capability and
filtering of noisy signals, under normal
conditions, utility power obtains via AC-DC
circuit the DC bus voltage which is then
converted to 220V AC output via the
inverter, so as to safeguard the data over
the entire network. Therefore, the power
used by the load is the purified sine wave
power via regulated voltage and regulated
frequency with noisy signals filtered.
Furthermore, Santak CASTLE Series 1K, 2K, 3K
UPS are connected through the RS232
communication port to Santak Power
Management software for power detection and
power monitoring, to integrate UPS and the
network server into one entity with power
status available at any time. Moreover, it
achieves the intelligent functions such as
timer-controlled self-inspection, automatic
disk-saving, automatic timer-controlled
power-on and power-off and record of power
status etc., to achieve the zero distance of
communication between the user and UPS.
Whenever utility power supply is
interrupted, the UPS will inform the server
immediately and gets ready for switching off
the unit and saving automatically all data
before performing the normal power-off
instruction. Even in an unattended network
environment, the UPS can still ensure data
safety of the network system.
APPLICATION
Servers, Data-Center Critical network
devices, Sensitive electronic equipment,
Telecom...
KEY
FEATURES
¡¤
True on-line double conversion technology
with advanced microprocessor control
¡¤
Wide input
voltage range
¡¤ Zero
transfer time
¡¤ Protection
against all type of power problems
¡¤ Self
test while start of the UPS
¡¤ Site
wiring fault warning
¡¤ On-battery
power-on function
¡¤ Smart
RS232 communication interface
¡¤
Intelligent
slot available
¡¤
Sealed lead-acid, maintenance
free battery |
|
|
|
|
|
TECHNICAL
SPECIFICATIONS
|
Product
Series
|
CASTLE
|
|
Model
|
C1K
|
C2K
|
C3K
|
|
Rated
Power
|
VA/W
|
1kVA
/ 0.7kW
|
2kVA
/ 1.4kW
|
3kVA
/ 2.1kW
|
|
Input
|
Nominal
Voltage
|
220VAC
|
|
Voltage
Range
|
115
~ 300VAC
|
|
Frequency
Range
|
46~54Hz(default),
user adjustable within 40~60Hz
|
|
Power
Factor
|
0.97
|
|
Connection
|
IEC320-10A
inlet
|
IEC320-16A
inlet
|
|
Output
|
Voltage
|
220VAC
¡À
2%
|
|
Frequency
|
46~54Hz
or 50Hz ¡À
0.2Hz (Line mode)
50Hz ¡À
0.2Hz (
Battery
mode)
|
|
Waveform
|
Sine
Wave
|
|
Distortion
|
3%
|
4%
|
|
Overload
Capability
|
108%~150%
for 30 sec., ³150%
for 300 ms
|
|
Current
Crest Ratio
|
3:1
|
|
Connections
|
IEC320
* 4
|
IEC320
* 6
|
IEC320
* 3 and
Terminal Block
|
|
Battery
|
Type
|
Sealed,
Maintenance free, Lead-Acid
|
|
Quantity
|
3
pieces
|
8
pieces
|
|
Back-up
Time (Full load)
|
5
min
|
9
min
|
5
min
|
|
Recharge
Time
|
5
hrs to 90% of capacity after full load discharge
|
|
Bypass
¡¡
|
Automatic
Transfer
|
on
overload and UPS failure
|
|
Before
UPS Power-on
|
Default
¡°NO¡±, user adjustable to ¡°YES¡±
|
|
Voltage
Range
|
80~264VAC
(Default), user adjustable within 80~286VAC
|
|
Transfer
Time
|
0
ms; less than 4 ms from inverter to bypass and vice
versa
|
|
LED
Indicators
|
Status
|
Load
level /
Battery
level,
Battery
,
Utility Power, Inverter, Bypass, Overload, Fault
|
|
Audible
Alarm
|
Bypass,
On battery mode,
Battery
low,
Overload, Fault
|
|
Acoustic
Noise
|
At
1 meter distance
|
45
dBA
|
50
dBA
|
|
Communications
|
DB-9
Port
|
RS-232
Serial Interface
|
|
Intelligent
Slot
|
Options:
WebPower, AS400 Card or WinPower CMC
|
|
Network
Surge Protection
|
RJ45
I/O port available for network or Fax/Modem
|
|
Environmental
|
Operating
Temperature
|
0
~ 40¡ãC
|
|
Operating
Humidity
|
20
~ 90% non-condensing
|
|
Weight
|
Net
(Kg)
|
13
|
31.5
|
32
|
|
Dimensions
|
W
x D x H (mm)
|
145
x 400 x 220
|
192
x 460 x 348
|
|
Model
|
C1KS
|
C2KS
|
C3KS
|
|
Rated
Power
|
VA/W
|
1kVA
/ 0.7kW
|
2kVA
/ 1.4kW
|
3kVA
/ 2.1kW
|
|
Input
|
Nominal
Voltage
|
220VAC
|
|
Voltage
Range
|
115
~ 300VAC
|
|
Frequency
Range
|
46
~ 54Hz(default), user adjustable within 40~60Hz
|
|
Power
Factor
|
0.97
|
|
Connection
|
IEC320-10A
inlet
|
IEC320-16A
inlet
|
|
Output
|
Voltage
|
220VAC
¡À
2%
|
|
Frequency
|
46~54Hz
or 50Hz ¡À
0.2Hz (Line mode)
50Hz ¡À
0.2Hz (
Battery
mode)
|
|
Waveform
|
Sine
Wave
|
|
Distortion
|
3%
|
4%
|
|
Overload
Capability
|
108%
~ 150% for 30 sec., ³150%
for 300 ms
|
|
Current
Crest Ratio
|
3:1
|
|
Connections
|
IEC320-10A
*4
|
IEC320-10A
*6
|
IEC320-10A
*3 and
Terminal Block
|
|
Battery
|
Type
|
Sealed,
Maintenance free, Lead-Acid
|
|
Nominal
DC Voltage
|
36VDC
|
96VDC
|
|
Back-up
Time
|
Depends
on the capacity of the external battery bank
|
|
Connection
|
External
Battery
Socket
|
|
Bypass
|
Automatic
Transfer
|
On
overload and UPS failure
|
|
Before
UPS Power-on
|
Default
¡°NO¡±, user adjustable to ¡°YES¡±
|
|
Voltage
Range
|
80
~ 264VAC (Default), user adjustable within 80 ~
286VAC
|
|
Transfer
Time
|
0
ms; less than 4 ms from inverter to bypass and vice
versa
|
|
LED
Indicators
|
Status
|
Load
level /
Battery
level,
Battery
,
Utility Power, Inverter, Bypass, Overload, Fault
|
|
Audible
Alarm
|
Bypass,
On battery mode,
Battery
low,
Overload, Fault
|
|
Acoustic
Noise
|
At
1 meter distance
|
45
dBA
|
50
dBA
|
|
Communications
|
| | | |